| Bolt Item
| Bolt Size
| "Install to" torque
| "Service Recheck" Torque
|
| Case Half Bolts
| ---
| 30 pound-feet
| 26-34 pound-feet
|
| Detent Plug
| ---
| 15 pound-feet
| 12-18 pound-feet
|
| Drain & Fill Plugs
| ---
| 30 pound-feet
| 30-40 pound-feet
|
| Front Bearing Retainer
| ---
| 16 pound-feet
| 12-20 pound-feet
|
| Front Output Yoke Nut
| ---
| 110 pound-feet
| Replace when Removed
|
| Rear Output Shaft Housing
| ---
| 30 pound-feet
| 26-34 pound-feet
|
| Oil Pump Mounting
| ---
| 14 pound-inches
| 12-15 pound-inches
|
| Range Lever Nut
| ---
| 22 pound-inches
| 20-25 pound-inches
|
| Rear Retainer Bolt
| ---
| 26-34 pound-feet
| ---
|
| Vacuum Switch
| ---
| 15-25 pound-feet
| ---
|
| Case Half Bolts
| ---
| 30 pound-feet
| ---
|
| Electric Mode Indicator Switch
| ---
| 15-25 pound-feet
| ---
|